Toolsa · Cat. no. TA-GK12000ISE
- 110 kg
- 13.5 kW / 18 hp at 3600 rpm
- Electric
- 50 Hz
zł7,390.00 net
zł9,089.70 gross
Not available online
We sell this model after a talk with our advisor · +48 732 081 091
Prefer to talk? +48 732 081 091

- 25 years on the market
- Own warehouse 1200 m²
- Returns up to 14 days
- Free delivery over PLN 3,000
Description
Toolsa GK12000iSE inverter generator – 11 kW peak, 10 kW rated, 230 V and 400 V
The Toolsa GK12000iSE is a petrol inverter generator with 11 kW of peak output and 10 kW of rated output, available as single-phase 230 V or three-phase 400 V. It is the largest unit in the Toolsa GK range and is built for backup power for a whole house, for workshops and for job sites running three-phase machines.
Toolsa GK generator close up
Power for the workshop and the home
10 kW rated output, a 32 l tank and up to 10 h of running at 50 % load.
- Rated power
- 10 kW
- Power max.
- 11 kW
- Continuous running time
- 10 h (at 50% load)

Power reserve for start-up
11kW
10 kW rated is continuous running, 11 kW peak is the reserve for starting equipment.
Choose within the GK family
- 6.8 kW more peak power
- 25 l bigger fuel tank
- 4,700 zł more (net)
- electric start at the push of a button, not recoil only
- 6.8 kW more peak power
- 25 l bigger fuel tank
- 7.6 kW more peak power
- 26.5 l bigger fuel tank
- 5,290 zł more (net)
- electric start at the push of a button, not recoil only
- 7.6 kW more peak power
- 26.5 l bigger fuel tank
GK12000iSE advantagewhat you pay for it

Fuel tank and cap
The cap closes a 32 l tank, and the capacity is marked on the cap itself.

Fuel level gauge
Check the fuel level on the gauge on top of the housing before you start the generator.

Muffler behind the grille
A spark arrestor stops sparks leaving the muffler; wait until the engine has cooled before touching it.

Recoil starter
Next to the electric start there is a recoil starter: pull the handle and the engine starts.
A clean sine wave for electronics
2 %
voltage regulation: automaticThe inverter keeps THD ≤ 2 % and voltage regulation is automatic.
On a single tank
10 h
at 50 % loadA 32 l tank gives up to 10 h of running at 50 % load.
Engine speed follows the load
The ESC switch matches engine speed to the load, which lowers fuel use and noise.
One-button start
Electric start fires the engine with a single press of the start/stop button.
A panel with CEE sockets and voltage selection

Every control on the panel labelled on one plate.
Protection at a glance
Indicators and protections show the generator state and protect connected equipment.
Wheels and handles for moving it

110 kg
net weightAt 110 kg, the transport wheels and pull-out handles let you reposition the generator around the site.
550cm³
Engine displacement
The GK550-Vi engine, with fuel consumption of ≤ 374 g/kWh, drives the inverter alternator.
Transport and tool compartment

Pull-out handlesfor moving the unit around the site 
Transport wheelswith a tread, for rolling the unit 
Hatch with a tool symbolcloses the compartment at the back 
Tool compartmentthe hatch folds down
Technical data
- Cat. no.
- TA-GK12000ISE
- Weight
- 110 kg
- Engine power
- 13.5 kW / 18 hp at 3600 rpm
- Startup
- Electric
- Frequency
- 50 Hz
- Voltage
- 230 V | 400 V
- Fuel
- Petrol
- Transport wheels
- Yes
- Displacement capacity
- 550 cm³
- Fuel consumption
- ≤ 374 g/kWh
- Engine model
- GK550-Vi
- Power supply
- 230 V
- Fuel tank capacity
- 32 l
- Power max.
- 11 kW
- Display
- LCD
- Degree of protection
- IP23M
- Rated power
- 10 kW
- Noise level
- 97 dB
- Class of insulation
- F
- Package dimensions
- 705 × 685 × 810 mm
- Engine oil capacity
- 1.4 l
- Phases
- 1 | 3
- Voltage regulation
- Automatic
- Continuous running time
- 10 h (at 50% load)
- THD
- ≤ 2 %
Documents
Videos
Questions and answers
How does the Toolsa GK12000iSE inverter generator differ from a standard AVR generator?
An inverter generator converts the alternator output electronically into a clean sine wave at 50 Hz and adjusts engine speed to the load. The GK12000iSE keeps total harmonic distortion at THD ≤ 2 % and regulates voltage automatically, so it can safely power computers, routers, boiler controllers and chargers. In a generator with AVR only, the engine runs at high speed all the time, which raises fuel consumption and noise, and the voltage waveform is less clean. For electronics an inverter generator is the right choice, while AVR suits mainly simple motor-driven tools.
What can the Toolsa GK12000iSE power and is 10 kW enough for a house?
The GK12000iSE delivers 10 kW of rated power (continuous operation) and 11 kW of maximum power (briefly, for example when a compressor or pump starts). It can power lighting, refrigerators, pumps, boiler controllers and construction tools and equipment with a combined load of up to 10 kW. Motor-driven appliances draw several times more current at start-up than in steady operation, so they should not be started at the same time. In a detached house 10 kW lets you run far more appliances at once than 3-4 kW generators.
How much fuel does the Toolsa GK12000iSE use and how long does it run on one tank?
The GK12000iSE fuel tank holds 32 l of petrol and gives up to 10 h of continuous running at 50 % load, which is about 3.2 l/h on average. The GK550-Vi engine, 550 cm³ and 13.5 kW (18 hp), uses up to 374 g of fuel per kWh. The ESC switch matches engine speed to the load, so fuel use drops and running time grows at lighter loads; at full load the tank empties faster. Refuel only with the engine stopped and cooled down.
How loud is the Toolsa GK12000iSE?
The sound power level of the GK12000iSE is LWA 97 dB according to the rating plate. This is the sound power of the unit, not the sound pressure measured at a given distance, so the noise you hear at a few metres is lower. Running with the ESC switch on reduces noise, because at low load the engine does not run at maximum speed. Place the generator away from windows and resting areas, and use ear protection near people working.
Does the Toolsa GK12000iSE start at the push of a button?
The GK12000iSE has electric start: the engine starts with a single press of the start/stop button, and the recoil starter stays on board as an additional option. With a 550 cm³ engine, electric start removes the effort of pulling the cord and lets you start the generator quickly in difficult conditions. Check the oil level daily or every 8 hours of operation; the low-oil alarm stops the engine but does not replace this check.
Can the Toolsa GK12000iSE be used outdoors and indoors?
The GK12000iSE has ingress protection IP23M and insulation class F (winding temperature up to 155 °C). IP23 means protection against solid objects larger than 12.5 mm and against water spray at up to 60° from vertical, and the letter M means the test was done with the engine running. It protects against splashes and is not approval for use in heavy rain, so in rain the generator should stand under a canopy. Exhaust gas contains odourless, toxic carbon monoxide, so run the generator only outdoors or in a well-ventilated place, never in a garage with the doors closed or in a cellar.
How does the Toolsa GK12000iSE differ from the other GK series models?
The GK series from Toolsa also includes: GK3500iS-Pro (manual start, 3.2 kW, 5.5 l tank, 21 kg, no wheels); GK3500iSE-Pro (electric start, 3.2 kW, 5.5 l tank, 22 kg, no wheels); GK4500iS-Pro (manual start, 3.8 kW, 7 l tank, 28.5 kg, wheels and pull-out handle); GK4500iSE-Pro (electric start, 3.8 kW, 7 l tank, 30 kg, wheels and pull-out handle). For comparison, the GK12000iSE: electric start, 10 kW, 32 l tank, 110 kg, wheels and pull-out handles. All models have an LCD display, insulation class F and THD ≤ 2 %. The full range is in the inverter generators category.
Can the Toolsa GK12000iSE be connected to a home installation?
Only a qualified electrician may connect a generator to a building installation, through a changeover switch (SZR) that rules out simultaneous operation of the grid and the generator and back-feeding into the grid. Without such a switch the connection can damage equipment and endanger utility workers. The 10 kW rated power and the clean sine wave (THD ≤ 2 %) are enough to supply selected circuits, for example lighting, a fridge, a controller and the circulation pump of a boiler. Other appliances can be plugged directly into the 230 V sockets of the generator.