Toolsa · Cat. no. TA-DV50
- 38,2 kg
- 1230 x 600 x 710 mm
- 50 Hz
- 50 kW
zł3,000.00 net
zł3,690.00 gross
Leasing for businesses
from zł100.19 net / month
Indicative calculation · you set the terms
ING leasing is not available for this amount — call us and we will arrange financing +48 732 081 091
In stock
48 pcs in stock
Same-day dispatch
order by 13:00
Arrives next day
on working days
Prefer to talk? +48 732 081 091

- 25 years on the market
- Own warehouse 1200 m²
- Returns up to 14 days
- Free delivery over PLN 3,000
Accessories
Toolsa TA-ER2C Electric Heater
Toolsa Electric Heater TA-ER3C
Toolsa TA-DV20 Indirect Diesel Heater (20 kW)
Toolsa TA-DV30 Indirect Diesel Heater (30 kW)
Toolsa Flue Pipe for Heaters (⌀110 mm × 1 m, TA-DV20 | TA-DV30 | TA-DV50)
Toolsa Flue Rain Cap for Heaters (⌀110 mm, TA-DV20 | TA-DV30 | TA-DV50)
Toolsa 90° Flue Elbow for Heaters (⌀114 mm, TA-DV20 | TA-DV30 | TA-DV50)
Toolsa Flexible Heater Ducting ⌀300 mm × 10 m with Hose Clamp (TA-DV50)- Need a different part?We will match it to your machine+48 732 081 091
Description
Toolsa TA-DV50 indirect diesel heater – maximum power and clean heat
Toolsa TA-DV50 is a high-output indirect (flued) diesel heater rated at a full 50 kW. With a large 50 l fuel tank and consumption of 4.6 l/h, it delivers long, economical and safe operation, effectively heating spaces of up to 800 m³.
Toolsa TA-DV50 up close
Clean heat with no fumes indoors
Indirect diesel heater rated at 50 kW for heating halls, workshops and buildings under construction.
- Power
- 50 kW
- Fuel consumption
- 4.6 l/h
- Fuel tank
- 50 l

Heat output for frosty days
50kW
Heat output matched to spaces of up to 800 m³ — choosing a heater starts with the hall volume.
Compare Toolsa heaters
- 20 kW more heat output
- 1.7 l/h higher fuel consumption
- 800 zł more (net)
- 30 kW more heat output
- 2.7 l/h higher fuel consumption
- 1,201 zł more (net)
TA-DV50 advantagewhat you pay for it
Clean heat in, flue gases out

Only warm air reaches the heated space, while combustion gases leave through the flue pipe. Combustion efficiency is approx. 80%.
4.6l/h
Economical running on one fill-up
The 50 l tank with a fuel level gauge lets the heater run through a full shift without topping up.

Flue gas outlet
The chimney stub takes a ⌀110 mm flue pipe that carries combustion gases out of the heated room.

Powerful heat output
The fan drives air around the combustion chamber and blows it out at the front, straight into the work area.

Easy repositioning
Wheels and a rear handle let you roll the cooled-down heater to a new spot on site.

Motor and fan
A high-power motor drives the fan, and the guard protects its blades from contact.
Assemble the flue system





The pipe, elbow and cap fit every model in the series, and a flexible duct can be connected to the hot-air outlet.
Temperature under control

The thermostat knob sets the temperature, while the displays show the set point and the current room temperature.

Heat exactly where needed
- Toolsa TA-DV50
Safety features as standard
If the flame goes out, the photocell cuts the power and shuts the heater down, and the thermal cut-out stops it if it overheats.
Predictable servicing
The maintenance schedule from the manual lets you plan servicing before the heating season and avoid downtime in frosty weather.
Complete site heating
Complete the flue with heater accessories, and heat open areas with a direct heater.
Technical data
- Cat. no.
- TA-DV50
- Weight
- 38,2 kg
- Dimensions
- 1230 x 600 x 710 mm
- Frequency
- 50 Hz
- Power
- 50 kW
- Fuel tank
- 50 l
- Fuel consumption
- 4.6 l/h
- Recommended area
- up to 800 m³
- Air flow
- 1,400 m³/h
In the box
1 pcsToolsa TA-DV50 Indirect Diesel Heater (50 kW)
1 pcsUser manual
Documents
Details
Fuel pressure gauge
An analogue operating pressure gauge lets you monitor the fuel pump and diagnose possible faults.
Fuel filler
A wide filler with a cap and gauge makes it easy to check the fuel level and refill the tank quickly.
Fuel tank
A large 50-litre tank provides over ten hours of operation without refuelling.
Transport wheels
Heavy-duty wheels and a transport handle make it easy to move the unit, even over uneven ground.
Flue
The exhaust outlet allows combustion gases to be vented safely.
Hot air outlet
A metal air outlet directs hot air into the space while keeping combustion fumes out.
Questions and answers
How much fuel does the Toolsa TA-DV50 oil-fired heater use?
The Toolsa TA-DV50 oil-fired heater consumes 4.6 l of fuel per hour at a heat output of 50 kW. It is the most powerful model in the Toolsa range of flued heaters: the Toolsa TA-DV30 heater rated at 30 kW uses 2.9 l/h, and the 20 kW TA-DV20 uses 1.9 l/h. The higher consumption translates into a recommended volume of up to 800 m³, more than one and a half times the 480 m³ of the TA-DV30.
How many hours does the TA-DV50 fuel tank last?
The fuel tank of the Toolsa TA-DV50 holds 50 l, which at a consumption of 4.6 l/h gives around 10 hours of continuous operation on a single fill. This is calculated from the tank capacity and the rated fuel consumption, so the actual time depends on operating conditions. The fuel level is easy to monitor thanks to the level indicator on the tank, and dual oil filters protect the fuel system from contamination.
Can the TA-DV50 heater be used in an enclosed room?
The Toolsa TA-DV50 is an indirect (flued) oil-fired heater in which combustion gases are separated from the heated air by a heat exchanger and led outside through a flue. Only clean air enters the room, which is why this type of heater is designed for heating enclosed spaces with a volume of up to 800 m³ at 50 kW. The condition is a correctly connected flue gas outlet. Safety is enhanced by an overheat thermostat, photocell flame monitoring and a post-shutdown cooling fan run.
What is the difference between a flued heater and a heater without a flue?
A flued (indirect) heater such as the TA-DV50 heats the air through a heat exchanger and directs the combustion gases out of the room through a flue. A heater without a flue (direct-fired), e.g. the Toolsa TA-D175 diesel heater rated at 51 kW, releases all its heat together with the combustion gases into the surroundings, so it is only suitable for open or well-ventilated spaces. At a similar output, the TA-DV50 heats up to 800 m³ with clean air, while the TA-D175 covers up to 1020 m³, but only where ventilation is not an issue.
Which duct fits the TA-DV50 heater?
The Toolsa TA-DV50 heater takes the Toolsa ⌀300 mm flexible duct, 10 m long, dedicated to this model. The duct fits onto the hot air outlet flange and lets you direct the stream of heat to work zones in a hall, warehouse or on a construction site. It is a duct for distributing warm air, not for exhausting combustion gases. The smaller TA-DV20 and TA-DV30 models work with a 250 mm diameter duct.